Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 15(19)2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37836037

RESUMO

A continuous-flow system based on a green and cost-effective monolithic starch cryogel column was successfully developed for removing methylene blue (MB). The proposed column exhibited high removal efficiency (up to 99.9%) and adsorption capacity (25.4 mg·g-1) for synthetic and real samples with an adsorbent cost of USD 0.02. The influence of various operation parameters, including the flow rate, initial concentration, column height, and temperature, on the MB removal efficiency was examined and reported. The MB removal efficiency remained >99% in the presence of potential interferences, highlighting the good performance of the cryogel column. The Yoon-Nelson dynamic model explained the MB adsorption better than the Bohart-Adams model, as indicated by the higher R2 values (R2 = 0.9890-0.9999) exhibited by the former and current trends of its parameters. The MB removal efficiency of the cryogel column remained at 62.7% after three reuse cycles. The wastewater containing MB collected from a local batik-production community enterprise in Phuket, Thailand was applied to the proposed continuous-flow system under optimum conditions, and results indicated that 99.7% of the MB present in 2.4 L of wastewater was removed. These results validate the excellent application potential of the cryogel column for the continuous-flow adsorption of MB. This study will facilitate future industrial applications and process designs of the continuous-flow system.

2.
Polymers (Basel) ; 15(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36771839

RESUMO

Toward the development of a practical and green approach for removing phosphate from water, a monolithic cryogel based on starch and calcium silicate hydrate (Cry-CSH) was employed as a phosphate adsorbent in a continuous flow system for the first time. The influence of flow rate, initial phosphate concentration, and adsorbent height on the adsorption efficiency was investigated. As the rate of flow and the initial concentration of phosphate increased, the total quantity of adsorbed phosphate dropped; however, the performance of the column was greatly enhanced by an increase in adsorbent height. The experimental data fit the Adams-Bohart model better than the Thomas and Yoon-Nelson models at the beginning of the adsorption process. To evaluate its applicability, the continuous flow system based on the monolithic Cry-CSH column was applied for the removal of phosphate from the discharge effluent of the Patong Municipality Wastewater Treatment Plant (Phuket, Thailand), achieving an excellent total adsorption of 94.61%.

3.
Molecules ; 29(1)2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38202812

RESUMO

Since currently used natural, nonrenewable phosphorus resources are estimated to be depleted in the next 30-200 years, phosphorus recovery from any phosphorus-rich residues has attracted great interest. In this study, phosphorus recovery from complex wastewater samples was investigated using continuous adsorption on cryogel column composited calcium silicate hydrate nanoparticles (CSH columns). The results showed that 99.99% of phosphate was recovered from a synthetic water sample (50 mg L-1) using a 5 cm CSH column with a 5 mL min-1 influent flow rate for 6 h while 82.82% and 97.58% of phosphate were recovered from household laundry wastewater (1.84 mg L-1) and reverse osmosis concentrate (26.46 mg L-1), respectively. The adsorption capacity decreased with an increasing flow rate but increased with increasing initial concentration and column height, and the obtained experimental data were better fitted to the Yoon-Nelson model (R2 = 0.7723-0.9643) than to the Adams-Bohart model (R2 = 0.6320-0.8899). The adsorption performance of phosphate was decreased 3.65 times in the presence of carbonate ions at a similar concentration, whereas no effect was obtained from nitrate and sulfate. The results demonstrate the potential of continuous-flow phosphate adsorption on the CSH column for the recovery of phosphate from complex wastewater samples.

4.
Polymers (Basel) ; 14(24)2022 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-36559910

RESUMO

A green monolithic starch cryogel was prepared and applied for the removal of methylene blue (MB) using a batch system. The influence of various experimental parameters on MB adsorption was investigated. High removal efficiency (81.58 ± 0.59%) and adsorption capacity (34.84 mg g-1) were achieved. The Langmuir model better fitted the experimental data (determination coefficient (R2) = 0.9838) than the Freundlich one (R2 = 0.8542), while the kinetics of MB adsorption on the cryogel followed a pseudo-second-order model. The adsorption process was spontaneous and endothermic with an activation energy of 37.8 kJ mol-1 that indicated physical adsorption. The starch cryogel was used for MB removal from a wastewater sample collected from a local Batik production community enterprise in Phuket, Thailand, and a removal efficiency of 75.6% was achieved, indicating that it has a high potential as a green adsorbent for MB removal.

5.
Molecules ; 27(21)2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36364112

RESUMO

Portable colorimetric hydrogel test kits are newly developed for the on-site detection of nitrite, nitrate, and phosphate in water. Griess-doped hydrogel was prepared at the bottom of a 1.5 mL plastic tube for nitrite detection, a nitrate reduction film based on zinc powder was placed on the inner lid of a second 1.5 mL plastic tube for use in conjunction with the Griess-doped hydrogel for nitrate detection, and a molybdenum blue-based reagent was entrapped within a poly(vinyl alcohol) hydrogel matrix placed at the bottom of a third 1.5 mL plastic tube to detect phosphate. These test kits are usable with on-mobile digital image colorimetry (DIC) for the on-site determination of nutrients with good analytical performance. The detection limits were 0.02, 0.04, and 0.14 mg L−1 for nitrite, nitrate, and phosphate, respectively, with good accuracy (<4.8% relative error) and precision (<1.85% relative standard deviation). These test kits and on-mobile DIC were used for the on-site determination of nutrients in the Pak Bang and Bang Yai canals, the main canals in Phuket, Thailand. The concentrations of nitrite, nitrate, and phosphate were undetectable to 0.60 mg L−1, undetectable to 2.98 mg L−1, and undetectable to 0.52 mg L−1, respectively.


Assuntos
Colorimetria , Nitritos , Colorimetria/métodos , Nitratos , Água , Hidrogéis , Nutrientes , Fosfatos , Plásticos
6.
Polymers (Basel) ; 14(11)2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35683913

RESUMO

A novel reinforced recycled expanded polystyrene (r-EPS) foam/natural fiber composite was successfully developed. EPS was recycled by means of the dissolution method using an accessible commercial mixed organic solvent, while natural fibers, i.e., coconut husk fiber (coir) and banana stem fiber (BSF) were used as reinforcement materials. The treatment of natural fibers with 5% (w/v) sodium hydroxide solution reduces the number of -OH groups and non-cellulose components in the fibers, more so with longer treatments. The natural fibers treated for 6 h showed rough surfaces that provided good adhesion and interlocking with the polymer matrix for mechanical reinforcement. The tensile strength and impact strength of r-EPS foam composites with treated fibers were higher than for non-filled r-EPS foam, whereas their flexural strengths were lower. Thus, this study has demonstrated an alternative way to produce recycled polymer/natural fiber composites via the dissolution method, with promising enhanced mechanical properties.

7.
Food Chem ; 389: 133085, 2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-35489258

RESUMO

To facilitate on-site nitrite determination for processed meat products, Griess-doped polyvinyl alcohol film was synthesized in the bottom of a plastic tube for in-tube determination. The tube's aperture was used to control the sample dimensions. Each sample, cut into eight sectors, was subjected to nitrite extraction by water. Use of tap water or commercial drinking water vs. ultrapure water was associated with < 2% differences in nitrite levels. The use of film and digital image colorimetry showed a low limit of detection (12.6 ± 0.5 µg L-1), good precision (1.0%RSD, n = 5 days), and good accuracy (93.2 ± 3.5 to 108.5 ± 1.8%recovery). Using these methods, sodium nitrite concentrations in 700 processed meat products for sale in Phuket, Thailand, were found to range from 6.8 ± 0.2 to 113.6 ± 1.3 mg kg-1. These results showed no significant differences with the HPLC standard method (p > 0.05, n = 45).


Assuntos
Produtos da Carne , Nitritos , Colorimetria/métodos , Produtos da Carne/análise , Álcool de Polivinil , Água
8.
J Environ Manage ; 301: 113923, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34634722

RESUMO

Phosphate is a major pollutant that deteriorates water quality and causes eutrophication, a novel calcium silicate hydrate composite cryogel (Cry-CSH) was thus successfully prepared for phosphate removal and recovery in this work. Calcium silicate hydrate (C-S-H) was mixed with the gel precursor (7.5% w/w) prepared from native starch and limewater (saturated calcium hydroxide solution as the cross-linker). The mixture was frozen and thawed for 3 cycles giving an interconnected macroporous composite. This had C-S-H nanoparticles (75 mg) immobilized on a monolithic floatable cryogel network (2.5 cm diameter × 1.0 cm height) enabling an easier recovery and without the losses that occur when using C-S-H nanoparticles. The phosphate adsorption reaches equilibrium at 120 min with adsorption capacity of 2.50 mgPO43-/gCry-CSH (65.42 mgPO43-/gC-S-H) under optimum conditions. Adsorption equilibrium data were well fit by the Freundlich isotherm model, while kinetic results were well fit by the pseudo second-order model. The calculated activation energy (Ea) of 43.9 kJ/mol indicates chemical adsorption, while a positive change in enthalpy (ΔH0, 19.3 kJ/mol) indicates the endothermic nature of phosphate adsorption. Cry-CSH can remove phosphate from wastewater and effluent samples with excellent removal efficiency (>98%). It can float on water surface for at least 105 days without damage, while its phosphate adsorbed form can be biodegraded within 10 days under soil buried conditions. Thus, this work demonstrated the significant potential of Cry-CSH for practical and environmentally friendly phosphate removal and recovery.


Assuntos
Fosfatos , Poluentes Químicos da Água , Adsorção , Compostos de Cálcio , Criogéis , Cinética , Silicatos , Amido
9.
Polymers (Basel) ; 13(22)2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34833272

RESUMO

Monolithic cryogels from starch were successfully synthesized and applied as alternative biodegradable filters for the first time. Rice flour was cross-linked with Ca2+ from limewater during gelatinization before being frozen and then thawed for three cycles. The resultant material was then soaked in ethanol for 3 h before incubation at 80 °C for 1 h, yielding monolithic material with interconnected pores in sizes of 51 ± 18 to 52 ± 15 µm without any need of freeze-drying. The cryogels possessed macroporous structure with specific surface areas from 1.1 to 4.3 m2g-1, they could adsorb water from 599 ± 27 to 635 ± 59% of their dry weight with low swelling ratios of 6.0 ± 0.3 to 6.4 ± 0.6 gwater/gcryogel, and could be applied as biofilters to remove suspended particles and reduce the light absorption of water sample from 25 ± 3 to 96 ± 5%. The prepared biofilters can be re-used up to three times, although they cost only USD 0.0004/piece. Complete weight loss resulted from burial in soil for 30 days, indicating environmentally friendly biodegradation and potential for environmental applications.

10.
Molecules ; 26(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34684744

RESUMO

Benzo(a)pyrene (BaP) has been recognized as a marker for the detection of carcinogenic polycyclic aromatic hydrocarbons. In this work, a novel monolithic solid-phase extraction (SPE) sorbent based on graphene oxide nanoparticles (GO) in starch-based cryogel composite (GO-Cry) was successfully prepared for BaP analysis. Rice flour and tapioca starch (gel precursors) were gelatinized in limewater (cross-linker) under alkaline conditions before addition of GO (filler) that can increase the ability to extract BaP up to 2.6-fold. BaP analysis had a linear range of 10 to 1000 µgL-1 with good linearity (R2 = 0.9971) and high sensitivity (4.1 ± 0.1 a.u./(µgL-1)). The limit of detection and limit of quantification were 4.21 ± 0.06 and 14.04 ± 0.19 µgL-1, respectively, with excellent precision (0.17 to 2.45%RSD). The accuracy in terms of recovery from spiked samples was in the range of 84 to 110% with no significant difference to a C18 cartridge. GO-Cry can be reproducibly prepared with 2.8%RSD from 4 lots and can be reused at least 10 times, which not only helps reduce the analysis costs (~0.41USD per analysis), but also reduces the resultant waste to the environment.


Assuntos
Benzo(a)pireno/química , Grafite/química , Extração em Fase Sólida/métodos , Benzo(a)pireno/análise , Cálcio/análise , Cromatografia Líquida de Alta Pressão , Criogéis/química , Química Verde/métodos , Limite de Detecção , Nanopartículas/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Amido/análise , Poluentes Químicos da Água/análise
11.
Mikrochim Acta ; 187(12): 643, 2020 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-33155149

RESUMO

A novel colorimetric sheet based on Griess reagent-doped mesoporous silica nanoparticles was developed for nitrite detection. Griess reagent was adsorbed on long-range ordered hexagonal mesoporous silica nanoparticles and developed ink-bottle pores with some disorder. When the modified nanoparticles were bound using starch to fabricate a thin (~ 313 µm) colorimetric sheet, spherical particles with a rougher surface and some distortion of their mesoporosity were observed. The sheet was used in conjunction with digital image colorimetry (DIC) and provides a wide linear range of 0.05 to 2.50 mg L-1 with a low detection limit (15.0 µg L-1-NO2-, equal to 4.5 µg L-1 NO2--N), good inter-day precision (1.93%RSD), and excellent precision (2.67% relative error). The colorimetric sensors produced from the sheet costs only 0.04 USD each, while the DIC uses a standard smartphone for photographic detection. The method developed offers an easier and cheaper means of conducting rapid on-site determination of nitrite in water with reliable quantitative results. Graphical abstract.


Assuntos
Colorimetria/instrumentação , Nanopartículas/química , Nitritos/análise , Dióxido de Silício/química , Concentração de Íons de Hidrogênio , Cinética , Limite de Detecção , Microscopia Eletrônica de Varredura , Porosidade , Reprodutibilidade dos Testes , Difração de Raios X
12.
Spectrochim Acta A Mol Biomol Spectrosc ; 243: 118812, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-32854085

RESUMO

Nowadays, nitrate (NO3-) and nitrite (NO2-) in aquatic ecosystems have increased due to various anthropogenic activities leading to deterioration of the ecosystem and can accelerate eutrophication. A Griess reagent-doped hydrogel test kit and a zinc powder-doped starch film were thus developed for on-site quantitative analysis of nitrate and nitrite. A clear colorless hydrogel tablet (diameter 1.5 cm 2 mm thickness) turned pink-violet after reacting with a standard solution of nitrite while the gray zinc-doped starch film (8.36 µm thickness) fabricated on the inner lid of small plastic tube was used for the in-tube reduction of nitrate to be nitrite. The use of this film followed by nitrite testing using the hydrogel tablet was used as a nitrate test. Both the materials developed were used in conjunction with digital image colorimetry (DIC) using smartphone application for on-site quantitative analysis of nitrite and nitrate. Good linearity (R2 > 0.99) ranges of 0.05 to 5 mg L-1 for nitrite and 1 to 50 mg L-1 for nitrate were obtained and detection limits of 50 µg L-1 for nitrite and 0.32 mg L-1 for nitrate were achieved. Good accuracy was obtained in terms of a relative error in a range of 0.75 to 2.68% with inter-day precision in a range of 0.20 to 0.50%RSD (n = 3). Quantitative analysis of nitrate and nitrite in 10 seawater samples taken in Phuket was in good agreement with the standard method (95% confidence level). Since the method developed employs test kits synthesized using biodegradable polymers and DIC using a smartphone application, it will allow the rapid on-site quantitative detection of nitrate and nitrite in a more convenient and environmentally friendly system.

13.
Anal Sci ; 36(10): 1261-1267, 2020 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-32475897

RESUMO

A tetramethylammonium hydroxide (TMAH)-doped starch film was developed for trinitrotoluene (TNT) detection. A purple Janowsky anion was obtained from the reaction of TNT with released TMAH. When the film was used in conjunction with digital image colorimetry (DIC), rapid quantitative analysis of TNT was achieved. The Red-Green-Blue (RGB) intensities analyzed from digital photographs of the purple product were used to establish calibration curves for TNT. A wide linear range (2.5 to 50 mgL-1) with good linearity (R2 > 0.99) was achieved for the quantification of TNT. Good precision (1.73 to 3.74%RSD) was obtained for inter-day tests (n = 5). The films were applied to test four post-blast soil samples and two positive results were observed. The concentrations quantified by DIC were in good agreement with spectrophotometry. The film was able to be stored in a freezer for 3 months with <4.3% change in performance.

14.
Anal Sci ; 36(5): 577-581, 2020 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-32201405

RESUMO

This work presents a novel, simple, rapid, and cost effective method for semi-quantitative analysis of arsenic(III) in water sample. The method was based on the digital image colorimetry (DIC) of difluoroboron-curcumin doped starch film (BF2-cur-film) and arsenic ion in water. A red BF2-cur-film (9.4 µm) was fabricated by entrapped difluoroboron-curcumin (BF2-curcumin, particle size of 60 - 113 nm) in tapioca starch film. When the standard solution of arsenic (1 mL) was added into small plastic tube containing BF2-cur-film on its inner lid, blue solution (λmax at 610 nm) was observed instead of orange color in blank solution (λmax at 495 nm). When BF2-cur-film was used in conjunction with DIC, a wide linear range of 0 - 10 mg L-1 with good linearity (R2 > 0.99) was obtained from green channel with low detection limit of 0.04 mg L-1. Moreover, good precision (0.9 - 1.2%RSD, n = 4 days) and accuracy (0.03% relative error) were also achieved.

15.
Spectrochim Acta A Mol Biomol Spectrosc ; 224: 117351, 2020 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-31336322

RESUMO

A tapioca starch film doped with curcumin nanoparticles was successfully fabricated and applied as a novel green colorimetric sensor for detection of boron in wastewater. Curcumin nanoparticles (curn, 30-90 nm) extracted from turmeric powder were used as a green probe, while tapioca starch was used as a natural support substrate. A yellow thin film (51 µm thick) fabricated on a used plastic spoon turned red-brown after immersion in boron solution (pH 9) for 15 min with excellent selectivity. The film costs only 0.0007 USD, while the cost of the sensor (curn-film on new plastic spoon) was 0.004 USD. After use the film could be completely washed from the plastic, it being biodegradable, while the used plastic spoon could be re-used to fabricate a new sensor at least 10 times. The good 1.52%RSD precision was obtained across three lots fabricated. When the curn-film was used in conjunction with digital image colorimetry (DIC), a simple and rapid quantification of boron was achieved. The green color layer in reflected light image of the red-brown product (IG) provided the highest sensitivity (64 ±â€¯1 a.u. L mg-1) and the lowest detection limit of 0.052 ±â€¯0.001 mg L-1. The intra-day testing (9 films) had 2.41 to 4.34%RSD, while the inter-day testing had 2.29 to 5.66%RSD (15 films, 5 days). Accuracy in terms of relative error for control samples (0.40 mg L-1) was +3.63%. Wastewater samples from Para-rubber wood processing plant were quantified by curn-film and DIC, giving 4248 ±â€¯391 mg L-1 boron concentration with no significant difference to ICP determination at 95% confidence level. The sensors after storage in a desiccator for a year gave readings changed by only +3.5% and -2.1% relative to freshly prepared sensors.


Assuntos
Boro/análise , Colorimetria/métodos , Curcumina/química , Nanopartículas/química , Amido/química , Limite de Detecção , Modelos Lineares , Manihot , Reprodutibilidade dos Testes
16.
Artigo em Inglês | MEDLINE | ID: mdl-30292149

RESUMO

Iron is an important trace element in environmental and biological systems, the development of simple and selective methods for the determination of iron is important. In this work, completely biodegradable tapioca starch was introduced as the substrate to entrap standard chromogenic probes (1,10-phenanthroline) for fabrication of a novel colorimetric sensor for ferrous. A clear plasticized thin film from tapioca starch was fabricated inside a small plastic tube as a portable test kit. A red complex was obtained by exposing the film to a ferrous solution, while no color changes were obtained with various other ions, indicating excellent selectivity. The developed films were applied in conjunction with a digital image colorimetry for quantification of ferrous. Calculated molecular absorption of the red complex showed the widest linear range (0 to 10 mg L-1) with good linearity (R2 < 0.9934) with ferrous concentrations. The developed method provided good inter-day precision (1.75 to 3.97%RSD, 5 days 15 sensors), good accuracy (+2.35% to +4.57% relative error), and low detection limit (0.09 ±â€¯0.01 mg L-1). The concentrations of ferrous ion in soil and water samples quantified by the developed method were not significantly different from atomic absorption spectrophotometry at 95% confidence level. The films were stable for at least three months.

17.
Food Chem ; 249: 154-161, 2018 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-29407918

RESUMO

A biodegradable colorimetric film was fabricated on the lid of portable tube for in-tube formaldehyde detection. Based on the entrapment of colorimetric reagents within a thin film of tapioca starch, the yellow reaction product was observed with formaldehyde. Intensity of the blue channel from the digital image of yellow product showed a linear relationship in the range of 0-25 mg L-1 with low detection limit of 0.7 ±â€¯0.1 mg L-1. Inter-day precision of 0.61-3.10%RSD were obtained with less than 4.2% relative error from control samples. The developed method was applied for various food samples in Phuket and formaldehyde concentration range was non-detectable to 1.413 mg kg-1. The quantified concentrations of formaldehyde in fish and squid samples provided relative errors of -7.7% and +10.8% compared to spectrophotometry. This low cost sensor (∼0.04 USD/test) with digital image colorimetry was thus an effective alternative for formaldehyde detection in food sample.


Assuntos
Colorimetria/métodos , Contaminação de Alimentos/análise , Formaldeído/análise , Alimentos Marinhos/análise , Animais , Colorimetria/economia , Colorimetria/instrumentação , Decapodiformes/química , Peixes , Espectrofotometria
18.
Forensic Sci Int ; 266: 202-208, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27314546

RESUMO

A cost effective hydrogel test kit was successfully developed for the detection of pre- and post-blast trinitrotoluene (TNT). A polyvinyl alcohol (PVA) hydrogel matrix was used to entrap the potassium hydroxide (KOH) colourimetric reagent. The easily portable test kit was fabricated in situ in a small tube to which the sample could be added directly. The test kit was used in conjunction with digital image colourimetry (DIC) to demonstrate the rapid quantitative analysis of TNT in a test soil sample. The built-in digital camera of an iPhone was used to capture digital images of the colourimetric products from the test kit. Red-Green-Blue (RGB) colour data from the digital images of TNT standard solutions were used to establish a calibration graph. The validation of the DIC method indicated excellent inter day precision (0.12-3.60%RSD) and accuracy (93-108% relative accuracy). Post-blast soil samples containing TNT were analysed using the test kit and were in good agreement with spectrophotometric analysis. The intensity of the RGB data from the TNT complex deviated by +6.3%, +5.1%, and -4.9% after storage of the test kits in a freezer for 3 months. The test kit was also reusable for up to 12 times with only -5.4%, +0.3%, and +4.0% deviations. The hydrogel test kit was applied in the detection of trace explosive residues at the scene of the recent Bangkok bombing at the Ratchaprasong intersection and produced positive results for TNT demonstrating its operational field application as a rapid and cost effective quantitative tool for explosive residue analysis.

19.
Sci Justice ; 55(6): 437-45, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26654079

RESUMO

Digital image colourimetry was successfully applied in the semi-quantitative analysis of ammonium nitrate using Griess's test with zinc reduction. A custom-built detection box was developed to enable reproducible lighting of samples, and was used with the built-in webcams of a netbook and an ultrabook for on-site detection. The webcams were used for colour imaging of chemical reaction products in the samples, while the netbook was used for on-site colour analysis. The analytical performance was compared to a commercial external webcam and a digital single-lens reflex (DSLR) camera. The relationship between Red-Green-Blue intensities and ammonium nitrate concentration was investigated. The green channel intensity (IG) was the most sensitive for the pink-violet products from ammonium nitrate that revealed a spectrometric absorption peak at 546 nm. A wide linear range (5 to 250 mgL⁻¹) with a high sensitivity was obtained with the built-in webcam of the ultrabook. A considerably lower detection limit (1.34 ± 0.05mgL⁻¹) was also obtained using the ultrabook, in comparison with the netbook (2.6 ± 0.2 mgL⁻¹), the external web cam (3.4 ± 0.1 mgL⁻¹) and the DSLR (8.0 ± 0.5 mgL⁻¹). The best inter-day precision (over 3 days) was obtained with the external webcam (0.40 to 1.34%RSD), while the netbook and the ultrabook had 0.52 to 3.62% and 1.25 to 4.99% RSDs, respectively. The relative errors were +3.6, +5.6 and -7.1%, on analysing standard ammonium nitrate solutions of known concentration using IG, for the ultrabook, the external webcam, and the netbook, respectively, while the DSLR gave -4.4% relative error. However, the IG of the pink-violet reaction product suffers from interference by soil, so that blank subtraction (|IG-IGblank| or |AG-AGblank|) is recommended for soil sample analysis. This method also gave very good accuracies of -0.11 to -5.61% for spiked soil samples and the results presented for five seized samples showed good correlations between the various imaging devices and spectrophotometer used to determine ammonium nitrate concentrations. Five post-blast soil samples were also analysed and pink-violet product were observed using Griess's test without zinc reduction indicating the absence of ammonium nitrate. This demonstrates significant potential for practical and accurate on-site semi-quantitative determinations of ammonium nitrate concentration.

20.
Food Chem ; 163: 87-91, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24912700

RESUMO

Colourimetric determinations of amylase activity were developed based on a standard dinitrosalicylic acid (DNS) staining method, using maltose as the analyte. Intensities and absorbances of red, green and blue (RGB) were obtained with iPhone imaging and Adobe Photoshop image analysis. Correlation of green and analyte concentrations was highly significant, and the accuracy of the developed method was excellent in analytical performance. The common iPhone has sufficient imaging ability for accurate quantification of maltose concentrations. Detection limits, sensitivity and linearity were comparable to a spectrophotometric method, but provided better inter-day precision. In quantifying amylase specific activity from a commercial source (P>0.02) and fish samples (P>0.05), differences compared with spectrophotometric measurements were not significant. We have demonstrated that iPhone imaging with image analysis in Adobe Photoshop has potential for field and laboratory studies of amylase.


Assuntos
Amilases/metabolismo , Telefone Celular , Pesqueiros , Animais , Colorimetria/métodos , Maltose/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...